{"product_id":"pad100-psda-potter","title":"PAD100-PSDA POTTER","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\u003cp dir=\"ltr\"\u003e\u003cbr\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003e The PAD100-PSSA (single-action) activates when the white “T”-bar is pulled downward, while the PAD100-PSDA (dual-action) requires lifting the front cover before pulling the “T”-bar. Once triggered, the handle cannot be restored without opening the unit, and opening the cover itself will initiate an alarm signal. Resetting the station is done with the Potter WS-93 key, which unlocks the front cover so the “T”-bar can be returned to its normal position before securing the housing. The device supports Class A, Class X, and Class B SLC wiring and is compatible with Potter IPA Series fire alarm control panels.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp dir=\"ltr\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eSingle-action or dual-action configuration options\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eRobust die-cast construction\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eReset key matches Potter fire alarm control panels\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eCompatible with IPA Series systems\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eSupports Class A, Class X, and Class B SLC operation\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eOperating voltage: 24 VDC\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eStandby\/Alarm Current: 200 μA max\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eTemperature Range: 32°F to 120°F (0°C to 49°C), indoor use\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eHumidity: 0–93% non-condensing\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eDimensions: 4.75\" H × 3.25\" W × 1.75\" D\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eMounting: Single-gang box or Potter P32-BB\/DBB\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eShipping weight: 1.46 lbs (PSDA)\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"POTTER","offers":[{"title":"Default Title","offer_id":49001353248987,"sku":"PPAD100PSDA","price":179.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0409\/8234\/7941\/files\/119694.png?v=1784751222","url":"https:\/\/nextsecuritycorp.com\/fr-ca\/products\/pad100-psda-potter","provider":"Next Security Corp","version":"1.0","type":"link"}