{"product_id":"sk-duct-silent-knight","title":"SK-DUCT SILENT KNIGHT","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp dir=\"ltr\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eThe \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eSK-DUCT Silent Knight Intelligent Air Duct Smoke Detector\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003e is designed to detect smoke and products of combustion in air moving through HVAC systems in commercial and industrial applications. Using \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003ephotoelectric smoke detection technology\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003e with the included \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eSK-PHOTOR sensor\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003e, the detector provides early warning of fire conditions within ductwork.\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eWhen smoke is detected, the unit communicates directly with the fire alarm control panel, which can be programmed to shut down fans, blowers, and other HVAC equipment to help limit the spread of smoke. The SK-DUCT features a rugged steel enclosure with a clear cover and a pivoting housing that allows fast, flexible installation on both round and rectangular ducts. It is engineered to perform reliably under demanding airflow, temperature, and humidity conditions.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003ePhotoelectric smoke detection for HVAC duct applications\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eOperates in airflow speeds from \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003e100 to 4,000 ft\/min\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eWide operating range: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003e-4°F to 158°F\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003e and \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003e0–95% RH (non-condensing)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eRugged \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003esteel backbox\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003e with clear, transparent cover\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003ePivoting housing supports \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eround or rectangular duct mounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eLED alarm indication\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003e and communication on sensor head\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eNew \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003ecover tamper signal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003ePatented sampling tube installs from front or back with \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eno tools required\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eEasy-to-clean design with \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003elarge terminal connection screws\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eHousing space available for mounting an \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eaddressable relay module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eUL Listed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SILENT KNIGHT","offers":[{"title":"Default Title","offer_id":49016994824411,"sku":"SSSKDUCT","price":321.39,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0409\/8234\/7941\/files\/401749.png?v=1784927354","url":"https:\/\/nextsecuritycorp.com\/fr-ca\/products\/sk-duct-silent-knight","provider":"Next Security Corp","version":"1.0","type":"link"}