{"product_id":"pad300-ductr-potter","title":"PAD300-DUCTR POTTER","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\u003ch2 dir=\"ltr\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cp dir=\"ltr\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eThe PAD300-DUCTR is an analog addressable duct smoke detector engineered to meet all local codes and NFPA requirements for HVAC duct installations. It uses a two-tube air sampling method, where the supplied 7\" exhaust tube and a selectable intake sampling tube draw air from within the duct for accurate detection. Sampling tubes are available in 2.5 ft., 5 ft., and 10 ft. lengths and can be trimmed to fit the duct size.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp dir=\"ltr\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eDesigned for easy installation, the unit mounts using a template and two sheet-metal screws without requiring removal of the clear cover. The housing includes a durable plastic backbox, a transparent cover secured by four captive screws, and accommodates installation without removing the detector head. The PAD300-DUCTR operates with addressable IPA and AFC\/ARC series panels and supports SLC Class A, Class X, and Class B wiring configurations. Built for demanding environments, it functions across air velocities ranging from 100 to 4,000 ft\/min and includes an integrated cover tamper switch for added system security.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003ch2 dir=\"ltr\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003e PAD300-DUCTR\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eItem Number:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003e 3992796\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eDetects smoke within HVAC duct systems\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eShips fully assembled with housing and detector head\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eCompatible with addressable IPA and AFC\/ARC series fire panels\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eSupports SLC Class A, Class X, and Class B configurations\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eInstallation possible without removing the detector head\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eListed air velocity range: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003e100–4,000 ft\/min\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eNo screens or filters required inside the housing\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eDurable plastic enclosure with clear cover\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eIntegrated cover tamper switch\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eUtilizes simple snap-in STN Series sampling tubes\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eIncludes one Form C relay\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eUUKL Listed\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003e for smoke control applications\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eCompatible with supervised PAD100-DRTS Remote Test Switch, MS-RA, MS-KA\/R, and MS-KA\/P\/R remote indicators\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp dir=\"ltr\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eOperating Voltage: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003e24 VDC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eCurrent Draw: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003e500 μA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eDetector Head Model: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003ePAD300-DD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eDetector Head Type: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003ePhotoelectric\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eAlarm Set Point: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eFixed at 2.5%\/ft (8%\/m)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eSensitivity Test Method: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eSelf-diagnostic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eAir Velocity: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003e100–4,000 ft\/min\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eAmbient Temperature: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003e32°F to 120°F (0°C to 49°C)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eHumidity: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003e10%–85% RH (non-condensing)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eHousing Material: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003ePlastic backbox with clear cover\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eFinish: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003eGray backbox, clear cover\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eDimensions: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003e13.5” L x 4.5” W x 2.25” H\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eMaximum Weight: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003e2 lbs.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eSampling Tubes: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003e2.5 ft., 5 ft., 10 ft.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\u003cspan style=\"background-color:transparent;color:#000000;\"\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;font-weight:400;text-decoration:none;\"\u003eRelay Contact Rating: \u003c\/span\u003e\u003cspan style=\"font-family:Arial,sans-serif;font-size:11pt;font-style:normal;text-decoration:none;\"\u003e\u003cstrong\u003e8A @ 30 VDC, 10A @ 120 VAC, 10A @ 250 VAC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"POTTER","offers":[{"title":"Default Title","offer_id":49001770451163,"sku":"PPAD300DUCTR","price":300.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0409\/8234\/7941\/files\/2967458.png?v=1784751297","url":"https:\/\/nextsecuritycorp.com\/products\/pad300-ductr-potter","provider":"Next Security Corp","version":"1.0","type":"link"}