(786) 485-5277
(786) 485-5277
FLEX 510 CONVENTIONAL FACP, 10 ZONES, 120 VAC, W/FLPS-7 POWER SUPPLY, RED
Shunt type trip
Programming cable (coiled)
Interface Cable: Non-condensing-93%: Nodes: 250: +32F to +120.2F (0C to +49C)
Line protector
Addressable manual station, for use with IdentiFlex 610, 632 and 650 systems
Dual action pull station, XP95 (Apollo) protocol
SINGLE ACTION PULL STATION, XP95 (APOLLO) PROTOCOL
Point identification device for monitoring contact device(s), designed for concealed mounting within an electrical backbox.
ADDRESSABLE POINT IDENTIFICATION DEVICE
Remote annunciator for Flex 410
Surface or flush backbox for RAN-7100
Control device for remote relay control, surface or flush mounting
Intelligent Loop Interface-Main Board
Intelligent loop interface, motherboard, XP95 protocol
INTELLIGENT LOOP INTERFACE; SUPPLEMENTAL; XP95 PROTOCOL
REPLACED 1100-1322..INI-VGC command center voice gateway, unshielded twisted pair, purchase fiber modules separate (FML-E3 and/or FSL-E3)
LCD keypad display
SMART LOOP PANEL TOUCHSCREEN ANNUNCITOR DISPLAY
BACK BOX, 2 UNIT
Back box, 6 unit (requires MCH-6)
6-unit mounting chassis for MBB-6
*CARBON MONOXIDE DETECTOR/h2
MULTI-CRITERIA PHOTOELECTRIC AND CO SENSOR
Multi-criteria detector with three sensing elements (Photo, Thermal, IR) - Velociti only, Bright White Color
Multi-module input, 6 zone sub-loop module
Multi-module output, 6 relay output module
MULTI-MODULE OUTPUT, 6 SIGNAL OUTPUT MODULE
Double action pull station
Manual Fire Alarm Pull station
Manual Fire Alarm Pull Stations SINGLE ACTION
NGA network graphic annuciator
The OSI-RI-GW intelligent addressable reflector-type linear optical beam smoke..detector is uniquely suited for protecting large open areas with hi...
View full detailsTWO WIRE IDC FOR N.O. DEVICES MONITOR MODULE
TEN INPUT MONITOR MODULE
E3 SERIES 9 AMPERE POWER SUPPLY
Network repeater, unshielded twisted pair
DUCT DETECTOR SMOKE PHOTOELECTRIC
DUCT DETECTOR PHOTOELECTRIC ANALOG ADDR WITH RELAY
SLP add-on SLC module, Apollo. 1 loop-126 devices. Required for SLP panel order
Smart Loop Panel Addressable FACP, Black enclosure with 7A power supply, LCD-SLP display. Requires SLC-PM or SLC95-PM for SLC loops.
SMART LOOP PANEL MAIN BOARD, REPLACEMENT BOARD. USE FOR REPLACEMENT OR RETROFITS.
SMART LOOP PANEL ADDRESSABLE FACP, RED ENCLOSURE WITH 7A POWER SUPPLY, LCD-SLP DISPLAY. REQUIRES SLC-PM OR SLC95-PM FOR SLC LOOPS.
SLP RETROFIT KIT FROM IF602 andamp; 7100 B-SLIM CABINET INCLUDES NEW MOUNTING PLATE AND OUTER RED DOOR REQUIRES PURCHASING: SLP-RB, FLPS-7-RB, LCD-...
View full detailsPHOTOELECTRIC DUCT DETECTORSMARTSCAN PROTOCOL